RMIS Part No. 500549 Rev. B Page 1
EAGLE Two-Wire Irrigation Controller
Specifications
1.0 BASIC FEATURES
1.1 Standard Programming Capability
The controller shall have:
• Connectivity up to 36 independent stations and one master valve.
• Four (4) independently controllable irrigation pro
rams, with five (5) selectable start
times, for a total of 20 possible irrigation cycles per day.
• Runtime(s) for each station can be set from 1 minute to 9 hrs 59 minutes per station,
in one-minute increments.
• Quick Station(s) programming to allow rapid pro
rammin
of an entire block of
stations, with the same runtime.
• Water Days for each program can be based on a seven-day cycle or a skip-by-day
cycle, which allows a pro
ram to skip from 1 to 30 days between waterin
cycles.
The water days can be restricted with the selection of ODD/EVEN calendar days.
• Manually activated system check/syrin
e cycle to sequentially run each station for a
user selectable time, with a range from one minute up to nine minutes.
• Manually activated program cycle to execute a pro
ram independently of its
programmed start time and water days.
• Manually activated station cycle to operate a sin
le station for a selectable period of
time from 1 minute to 9 hours 59 minutes.
• Programmable Master Valve to utilize and control a Master Valve on a per pro
ram
basis.
• Confi
urable Master Valve Type to select either a Normally Open Master Valve or a
Normally Closed Master Valve.
• Programmable Pump independent of the Master Valve on a per program basis.
• Programmable stacking or non-stackin
operation of the pro
rams. In the event that
pro
rammed start times either within a pro
ram or between pro
rams should overlap,
or coincide, the controller can either be pro
rammed to sequentially execute one
program after the other program has completed (Stack Mode) or to simultaneously
execute all programs as their programmed start times occur (No Stack Mode).
• Programmable delay time between station executions. The pro
rammed delay time
can be between 0 to 255 seconds (4 minutes 15 seconds). This capability allows slow-
closing valves to completely shut off, before the next valve turns on.
1.2 Water Conservation Features
The controller shall have:
• Flow sensing and control (refer to section 2.0)
• Evapotranspiration (ET) based scheduling (refer to section 3.0)
• Percenta
e ad
ustment on a per pro
ram basis to allow an increase or decrease of all
station runtimes within that pro
ram. The percenta
e shall allow ad
ustment from 0 to
300% in 1% increments.
• Programmable rain shut off in order to delay the start of irri
ation after a rain storm.
he controller shall not water durin
the pro
rammed delay period (from one to seven
days). After the delay period has expired the controller shall return to the automatic
Commentaires sur ces manuels